Zero Halogen, Flame Retardant, Low
Smoke, Single Core Unsheated Copper Cables
For Working Voltage up to 1100 Volts |
| REFERENCE STANDARDS |
|
»
INTERNATIONAL :
»
NATIONAL :
|
BS 4066-1 & 3, BS
6724, VDE 0207
IEC 332-1 & 3, IEC 754-1 |
| Conductor |
Bright annealed bare copper
of high electrolytic grade drawn to fine strands, multi
strands bunched together rope shaped wire for uniformity
of conductor dia, resistance, dimensions and flexibility
etc. The diameter of the conductor is so uniform that
strands do not get cut when stripping the insulation thus
conductor gives perfect conductivity which eliminates
spot heating and sparking. |
| Insulation |
Specially formulated grade of Halogen
Free Flame Retardant compound is used. The performance
of the Cable in fire situation is exceptionally good.
The insulation does not melt, drip or spread the fire
conditions. The smoke is negligible, transparent and non-toxic. |
| Marking |
The Cable are printed with generic
marking ELKAY - ZHFR |
| Color |
Skin colouring in various colour like
Red, Yellow, Blue, Black, Green |
| Packing |
90 mts. length in attractive cartoons. |
| Normal
Area of Conductor |
Number/
Nom. Dia. |
Number/
Nom. Dia. For Unilay |
Insulation
Thickness (Nom.) |
Approx.
Overall Diameter |
Current
Carrying Amps. |
Resistance
(Max.) per km |
| Sq.mm. |
mm. |
mm. |
mm. |
mm. |
Concealed |
Casing |
@
20°C Ohms. |
| 1.0 |
14/.3 |
19/0.26 |
0.7 |
2.8 |
11 |
12 |
18.10 |
| 1.5 |
22/.3 |
19/0.32 |
0.7 |
3.1 |
13 |
16 |
12.10 |
| 2.5 |
36/.3 |
37/0.29 |
0.8 |
3.8 |
18 |
22 |
7.41 |
| 4.0 |
56/.3 |
37/0.37 |
0.8 |
4.4 |
24 |
29 |
4.61 |
| 6.0 |
84/.3 |
61/0.35 |
0.8 |
5.0 |
31 |
37 |
3.30 |
| Test |
Specification |
FRZH
Typical Value |
FRPVC
Typical Value |
Ordinary
PVC
Typical Value |
| Critical Oxygen Index |
ASTM-D 2863 |
>31 |
>29 |
>22 |
| Temperature Index |
ASTM-D 2863 & BICC Hand Book Chapter
No. 6 |
>300°C |
>250°C |
>200°C |
| Smoke Density |
ASTM-D 2843 |
<20% |
<80% |
<90% |
| Acid Gas Generation |
IEC 754-1 |
<2% |
<20% |
<40% |
| Flammability |
IEC 332-1 |
Flame to extinguish with in 15 sec. |
Flame to extinguish with in 30 sec. |
Flame to extinguish with in 60 sec. |