Quick Product Reference
Product Constituents
Product Description
Telecom Cables >>
Instrumentation/Data Cables >>
Power/Control/Signal Cables >>
Special Application Cables >>
UL/Flexible/House Wiring >>
Home
<
Telecom Cables
< Coaxial Cables
BC: Bare Copper
CCS: Copper claded steel
CCA: Copper claded aluminium
PE: Polyethylene
FPE: Foamed polyethylene by gas injection
AL: Aluminium
AL/pet: Aluminium+pet foil
AL/pet/AL: Al+PET+Al foil
CU/pet: Copper+pet foil
PVC: Polyvinyl Chloride
TS: Tri shielding
QS: Quad Shielding
SPECIFICATION
RG58C/U
RG59/U
RG6/U
RG11/U
Nominal Impedance
OHM
50
+
2
75
+
3
75
+
3
75
+
3
Capacitance
pF/m
98
53
53.5
52.4
Velocity Radio
%
66
82
85
85
NOMINAL ATTENUATION
at 55MHZ
dB/100m
11.4
6.73
5.52
3.15
at 211MHZ
dB/100m
22.3
12.47
10.00
6.23
at 250MHZ
dB/100m
23.0
13.45
10.82
6.72
at 450MHZ
dB/100m
37.3
17.72
14.43
9.02
at 750MHZ
dB/100m
51.0
22.87
18.54
11.97
at 860MHZ
dB/100m
52.2
24.67
20.01
13.05
at 1000MHZ
dB/100m
58.8
26.64
21.49
14.27
at 1350MHZ
dB/100m
at 1750MHZ
dB/100m
at 2050MHZ
dB/100m
at 2150MHZ
dB/100m
at 2400MHZ
dB/100m
RETURN LOSS
(30~300) MHZ
db
>35
>20
>20
>20
(300~860) MHZ
db
>30
>20
>20
>20
(860~2400)
db
Inner Conductor
mm
19/0.18TC
0.81BC/CCS
1.02BC/CCS
1.63BC/CCS
Dielectric
mm
PE2.95
FPE3.66
FPE4.57
FPE7.11
Outer conductor
:Foil
AL foil
AL foil
AL foil
:Braid
TC
AL wire
AL wire
AL wire
Coverage
%
90
40
40
40
Sheath diameter
mm
PVC5.0
PVC6.10
PVC6.91
PVC10.03
Min. bending radius
mm
15/50
40/80
35/70
50/100
MAIN USING
LAN
data coaxial
cable
Drop cable for antenna, CATV
terminals &
satellite
connections
Drop cable for antenna, CATV
terminals &
satellite
connections
Distribute
cable for
LAN
NOTE
RG59TS
RG59QS
RG59B/U is
available
RG6TS
RG6QS
RG6Messenger
is available
RG11TS
RG6QS
RG11 Messenger
is available
Copyright © 2003 Elkay Telelinks Ltd. All right reserved
Site by
SMARTech