Equipment wires and jumper
wires are utilised for cross connections on instrumentent
panels and electronic industry on all types of electronic
equipment.
Construction
Conductor: Solid tinned copper wire to
BS 4109 Insulation: PVC to BS 6746 Option: Single or bi-colours
No.
of Pairs
Conductor
diameter
(mm)
Conductor
Cross-Section
Area (sq.mm.)
Conductor
Insulation
Thickness (mm)
Overall
Dia.
(mm)
Conductor
Resistance
at 20°C
(Ω/km)
Insulation
Resistance
(MΩ/km)
1
0.4
0.126
0.2
0.85
150.0
50
1
0.5
0.20
0.2
0.95
97.5
50
1
0.6
0.28
0.2
1.05
65.0
50
1
0.9
0.64
0.25
1.6
29.0
50
2
0.6
0.28
0.2
2.0
65.0
50
3
0.6
0.28
0.2
2.2
65.0
50
4
0.6
0.28
0.2
2.4
65.0
50
5
0.6
0.28
0.2
2.6
65.0
50
Options: Jumper wires are available in stranded conductors.